Battery Bank Runtime Calculator with Inverter Efficiency & DoD

Estimate your battery bank's operational time, considering crucial factors like inverter efficiency and the desired depth-of-discharge (DoD) to protect your batteries and plan your power usage accurately.

batteryruntimeinverterefficiencydepth of dischargedodoff-gridsolarpowerenergy storage

Results

Enter your inputs and run the calculation to see results.

Sponsored

📊

Trusted by the community

0 people used this tool today

Community Discussion & Cases

Share your experience or submit a case study on how you use this tool.

You might also need...

FAQ

What is Depth of Discharge (DoD) and why is it important?
DoD refers to the percentage of a battery's capacity that has been discharged. It's crucial because regularly discharging batteries too deeply (high DoD) significantly reduces their lifespan. For instance, a lead-acid battery cycled to 80% DoD will have significantly fewer cycles than one cycled to 50% DoD. This calculator helps you plan within your recommended DoD.
How does inverter efficiency affect my battery bank runtime?
Inverter efficiency represents the percentage of DC power from your batteries that is successfully converted into usable AC power for your appliances. No inverter is 100% efficient; some energy is always lost as heat during the conversion process. A lower efficiency means more power must be drawn from your batteries to supply the same AC load, thus reducing your overall runtime.
Can I discharge my battery bank to 100% DoD?
While technically possible, it is generally not recommended for most battery chemistries, especially lead-acid. Discharging to 100% DoD can severely shorten the battery's lifespan and potentially damage it. Lithium-ion batteries can tolerate higher DoD (often 80-90%), but even they benefit from not being fully depleted. Always consult your battery manufacturer's specifications.
What factors can affect an inverter's efficiency?
Inverter efficiency can vary based on several factors, including the load percentage (many inverters are most efficient at 70-90% of their rated capacity), ambient temperature, the type of inverter (e.g., pure sine wave vs. modified sine wave), and its overall quality and design. Modern, well-designed inverters typically offer higher efficiencies.
What does 'Battery Bank Capacity (Ah)' mean?
Ampere-hours (Ah) is a measure of electric charge, indicating how much current a battery can deliver for a certain amount of time. For example, a 100Ah battery can theoretically deliver 100 amps for one hour, or 10 amps for 10 hours. When combined with the battery's voltage (V), it allows us to calculate the total energy (Wh) stored in the bank.
My calculator shows 'Infinity' runtime. What does that mean?
An 'Infinity' runtime typically means you've entered a total appliance load of zero watts. If there's no load drawing power from your battery bank, and you have available energy, the battery will theoretically last indefinitely (until factors like self-discharge, which this calculator doesn't account for, become significant).
How can I extend my battery bank runtime?
You can extend runtime by increasing your battery bank's capacity (either by adding more batteries to increase Ah or by increasing system voltage), reducing your total appliance load (e.g., using more energy-efficient appliances), upgrading to a more efficient inverter, or by allowing for a deeper (but still safe) depth of discharge, if your battery chemistry permits.

Related tools

Auto-curated

Learn more

Why use this Battery bank runtime with inverter efficiency and depth-of-discharge?

When designing an off-grid power system, equipping an RV, or setting up a robust backup power solution, one of the most critical questions is: "How long will my batteries last?" While a simple calculation of total battery amp-hours might seem sufficient, it often leads to wildly optimistic and inaccurate estimates. This is where the Battery Bank Runtime Calculator with Inverter Efficiency & Depth of Discharge becomes an indispensable tool. Traditional battery runtime calculations frequently overlook two major factors that significantly impact real-world performance: inverter efficiency and the recommended depth of discharge (DoD). Your inverter, which converts the battery's DC power into usable AC power for most household appliances, isn't 100% efficient. A portion of the energy drawn from your batteries is lost as heat during this conversion, meaning your batteries have to work harder to deliver the same amount of power to your devices. Equally important is the concept of Depth of Discharge (DoD). Discharging batteries too deeply not only reduces their available runtime but, more critically, drastically shortens their overall lifespan. Most battery manufacturers recommend a specific maximum DoD (e.g., 50% for lead-acid, 80-90% for lithium-ion) to ensure you get the maximum number of charge/discharge cycles from your investment. Failing to account for this can lead to premature battery replacement and unexpected power outages. By incorporating both inverter efficiency and your chosen depth of discharge, this calculator provides a far more realistic and actionable runtime estimate. This accuracy empowers you to make informed decisions about your battery bank sizing, appliance usage, and overall system design, helping you avoid costly mistakes and ensuring reliable power when you need it most.

How the calculation works

Understanding the logic behind this calculator demystifies the process of determining battery bank runtime. It breaks down the complex interplay of battery capacity, appliance loads, inverter efficiency, and depth of discharge into a series of straightforward steps: **Step 1: Calculate Total Battery Energy (Watt-hours - Wh)** First, we determine the total energy stored in your battery bank. This is done by multiplying the battery bank's capacity in Ampere-hours (Ah) by its voltage (V). The result is the total Watt-hours (Wh) available, representing the absolute maximum energy your batteries can hold. *Formula: `Total Battery Energy (Wh) = Battery Capacity (Ah) × Battery Voltage (V)`* **Step 2: Determine Usable Battery Energy (Wh) based on DoD** Next, we apply the recommended Depth of Discharge (DoD) to ensure battery longevity. This step calculates how much of the total stored energy you can actually use without damaging your batteries. For example, if you have 2400 Wh total and a recommended DoD of 50%, you can only safely use 1200 Wh. *Formula: `Usable Battery Energy (Wh) = Total Battery Energy (Wh) × (DoD% / 100)`* **Step 3: Account for Inverter Efficiency** Your inverter consumes power to convert DC from your batteries to AC for your appliances. Therefore, the actual power drawn from your batteries is higher than the power consumed by your appliances. We divide your total appliance load by the inverter's efficiency (as a decimal) to find the true power demand on your battery bank. *Formula: `Actual Power Drawn from Battery (W) = Total Appliance Load (W) / (Inverter Efficiency% / 100)`* **Step 4: Calculate Estimated Runtime (Hours)** Finally, we divide the usable energy from your battery bank (from Step 2) by the actual power drawn from the battery (from Step 3) to get the estimated runtime in hours. *Formula: `Estimated Runtime (Hours) = Usable Battery Energy (Wh) / Actual Power Drawn from Battery (W)`* **Example:** Let's say you have a 200Ah, 12V battery bank, a 500W appliance load, an inverter efficiency of 90%, and a recommended DoD of 50%: 1. Total Battery Energy: `200 Ah * 12 V = 2400 Wh` 2. Usable Battery Energy: `2400 Wh * (50 / 100) = 1200 Wh` 3. Actual Power Drawn from Battery: `500 W / (90 / 100) = 555.56 W` 4. Estimated Runtime: `1200 Wh / 555.56 W = 2.16 hours` The calculator also converts the runtime from hours to days for easier interpretation.

Common mistakes in Battery bank runtime with inverter efficiency and depth-of-discharge

Calculating battery runtime can be tricky, and several common pitfalls can lead to inaccurate estimates and potential system failures. Being aware of these mistakes can help you design a more robust and reliable power system. **1. Ignoring Inverter Efficiency:** This is perhaps the most frequent oversight. Many people simply divide their battery's total Wh by their appliance's wattage, completely neglecting the energy lost during the DC-to-AC conversion. This invariably leads to an overestimation of runtime and can leave you without power sooner than expected. **2. Overlooking Depth of Discharge (DoD):** While a battery might technically hold a certain amount of energy, discharging it fully will drastically reduce its lifespan. Failing to factor in a conservative DoD (e.g., 50% for lead-acid, 80-90% for lithium-ion) leads to unrealistic runtime expectations and premature battery degradation, costing you more in the long run. **3. Underestimating Total Appliance Load:** It's easy to forget intermittent loads, phantom loads, or startup surges. Forgetting appliances that cycle on and off (like refrigerators or water pumps), or neglecting the power draw of chargers and small electronics, will result in an underestimation of your average power consumption. Always try to measure actual loads or add a safety margin to nameplate ratings. **4. Using Peak Inverter Efficiency for Average Loads:** Inverters typically have a 'peak' efficiency, often achieved at a specific load percentage (e.g., 70-90% of their rated capacity). Their efficiency can drop significantly at very low or very high loads. Assuming peak efficiency for all operating conditions will lead to an optimistic runtime. It's often better to use a slightly lower, more conservative average efficiency for your calculations. **5. Neglecting Peukert's Law (for Lead-Acid Batteries):** While this calculator doesn't directly incorporate it, Peukert's Law states that for lead-acid batteries, the usable capacity decreases as the discharge rate increases. If you have a very high appliance load relative to your battery bank size, your actual usable capacity might be less than calculated. For critical systems with high loads, this is an advanced consideration. **6. Ignoring Battery Age and Temperature:** As batteries age, their internal resistance increases, and their overall capacity diminishes. Similarly, extreme cold temperatures can significantly reduce a battery's effective capacity and efficiency. While these factors are outside the scope of a basic runtime calculator, they are crucial for long-term system performance and should be considered in real-world applications. **7. Not Considering Self-Discharge:** All batteries slowly lose charge even when not in use. While negligible for short periods, for systems intended for long-term storage or infrequent use, self-discharge can become a factor impacting true runtime over extended durations.

Data Privacy & Security

In an era where digital privacy is paramount, we have designed this tool with a 'privacy-first' architecture. Unlike many online calculators that send your data to remote servers for processing, our tool executes all mathematical logic directly within your browser. This means your sensitive inputs—whether financial, medical, or personal—never leave your device. You can use this tool with complete confidence, knowing that your data remains under your sole control.

Accuracy and Methodology

Our tools are built upon verified mathematical models and industry-standard formulas. We regularly audit our calculation logic against authoritative sources to ensure precision. However, it is important to remember that automated tools are designed to provide estimates and projections based on the inputs provided. Real-world scenarios can be complex, involving variables that a general-purpose calculator may not fully capture. Therefore, we recommend using these results as a starting point for further analysis or consultation with qualified professionals.

Fact-checked and reviewed by CalcPanda Editorial Team
Last updated: January 2026
References: WHO Guidelines on BMI, World Bank Financial Standards, ISO Calculation Protocols.
Calculate Battery Bank Runtime with Inverter Efficiency & Depth of Discharge